f10
Technical Data
Finish Matte to semi-gloss. Successive coats will increase sheen depending upon substrate.
Solids Content 26%
Solvent Water only
Dry Time To touch = 1 hour
To recoat = 2 to 4 hours
To normal traffic = 24 hours
Primer None
Coverage Over Broom Finish
200 to 300 ft.2

Over Smooth Surface
400 to 600 ft.2

FRITZ Concrete Sealer is a clear wearable high solids liquid acrylic designed to be applied to cementitious overlayments and other masonry surfaces to provide high gloss and stain protection. FRITZ Concrete Sealer is best used as a two coat minimum application and is designed for interior use only. FRITZ Concrete Sealer is durable, easy to apply, quick drying, UV stable and non-flammable.

Applicable Substrates

Use FRITZ Concrete Sealer indoors residentially and commercially on clean masonry surfaces both vertically and horizontally where gloss and stain protection is desired. SUPRACRETE Concrete Sealer is well suited for use over FRITZ overlayment product and non oil-based stains. Only apply FRITZ Concrete Sealer to masonry. Do not apply to other surfaces or over paint. All surfaces must be clean. FRITZ Concrete Sealer can be applied over itself in heavily trafficked areas or other areas of excessive wear. Do not apply FRITZ Concrete sealer over oil-based stains; use an appropriate sealer recommended by the stain manufacturer.

Substrate Preparation

New Work: FRITZ Concrete Sealer can be applied over FRITZ Overlayment within 4 to 6 hours of final set. If the overlayment has been decoratively stained, use guidelines set by the stain provider for timing of application.

Old Work: It is recommended that a small test area be evaluated prior to determining the suitability for the entire substrate. Clean substrates with a pH neutral cleaner followed with a clear water rinse. Never use solvents, acid etching solutions or sweeping compounds to prepare the substrate. Allow substrate to dry.

Tools

Nylon Paint Brush, 3/8ths inch nap Paint Roller, Paint Roller Tray. FRITZ Concrete Sealer was not designed for application using spray equipment.

Application

Apply two thin coats allowing 2 to 4 hours between coats. The environment must be between 50 and 90 degrees F. Do not stir or agitate product. Shake the 1 gallon container gently once or twice, but do not create air bubbles within the product. (Allow product to sit for one hour if it has bubbles.) Pour the liquid into the paint tray. Dampen the roller (or brush) in the tray evenly. Apply evenly working away from a wet edge. Apply smoothly and evenly. Roll out streaks and puddles. It is not recommended to back roll previously applied still wet areas. If the environment causes the liquid to become viscous add only small amounts of clean potable water to thin. When using over non oil-based stains apply FRITZ Concrete Sealer at the time recommended by the stain manufacturer.

CAUTION

This is a cementitious type product that could be irritating to the eyes and skin. Rubber gloves are recommended. Avoid contact with eyes or prolonged contact with skin. In case of contact with skin, flush the thoroughly with water. In case of contact with eyes, flush with water, then seek prompt medical attention.

get adobe reader Some documents require Adobe Reader
If you've not yet installed Adobe Reader on your computer, click here to download and install it.
specs and resources
pdf doc Section 09656 - Resilient Terrazzo Tile
Word (.doc) or PDF format - click icon to download
Three Part
CSI Specifications

spec wizard specs bim objects green
Material Safety Data Sheets (MSDS)
All flooring and tile products